Swage Diameters - Before and After Process.

The data detailed below is a table of typical BEFORE and AFTER swage dimensions. This table is a REFERENCE GUIDE ONLY. It is the sole responsibility of the person or company swaging to ensure that the correct dies have been used and that the swage has been completed correctly.

Wire Size
(mm)

Diameter Before Swaging (mm)

Diameter After Swaging (mm)

3

6.35/6.22

5.56/5.44

4

7.54/7.42

6.35/6.23

5

9.12/9.00

7.95/7.83
6 12.54/12.42 11.12/10.95
7 14.30/14.18 12.70/12.50
8 16.13/16.01 14.30/14.07
10 17.85/17.73 15.90/15.70
12 21.44/21.32 19.05/18.82
14 25.00/24.88 22.23/22.00
16 28.17/28.05 25.40/25.15
19 34.52/34.40 31.75/31.44
22 40.46/40.21 36.50/36.20
26 46.02/45.77 41.28/40.97